Input Rated Voltage, Frequency 3-phase (4T) AC 380V, 47-63Hz;  1-phase (2S) AC 220V, 47-63 Hz
Allowed Voltage Range 3-phase (4T) AC 320V~480V;   1-phase (2S) AC 160V~260V
Output Voltage 14T,0~480V;12S,0~260V
Freqency Vector control: 0~500Hz  V/F control: 0~1000Hz
Overload Capacity 150% rated current 60s, 180% rated current 5s;  195% rated current 0.5s
Control Mode V/F control, speed-sensor-less vector control (SVC)
Control Character Frequency Setting Resolution Analog Input Maximum frequency X0.025%
Digital Setting 0.01Hz
V/F Control V/F Curve(voltage frequency character) Three types: linear type; multi-point type; Nth power type V/F curve (to the power of 1.2, 1.4,1.6,1.8,2)
V/F separation 2 types: full separation, half separation
Torque  Compensation Manual setting: 0.0~30% of rated output Automatic compensation: according to output current and motor parameter
Automatic Currentlimiting and Voltage-limiting During acceleration, deceleration or steady running, detect automatically the current and voltage of motor stator, and control it within bounds based on unique algorithm, minimize fault-trip chanc
Senseless Vector Control Voltage Frequency Character Adjust pressure/frequency ratio according to motor parameter and unique algorithm
Torque Character Starting torque:150% rated torque at 1.0Hz (VF control)

150% rated torque at 0.25Hz ( SVC)

Running speed steady-state accuracy: ≤±0.2% of rated synchronous speed

Speed fluctuation: ≤±0.5% rated synchronous speed

Torque response: ≤20ms ( SVC)

Motor Parameter Self-measurement Being able to detect parameter automatically under static state and dynamic state of motor, thus guarantee an optimum control.
Current and Voltage Restrain Current closed-loop control, free from current impact, perfect restrain function of overcurrent and overvoltage
Undervoltage Restrain during Running Specially for users with a low or unsteady voltage power grid: even lower than the allowable voltage range, the system can maintain the longest possible operating time based on its unique algorithm and residual energy allocation strategy
Typical Function Multi-velocity and Traverse Operation 16 segments programmable multi-velocity control, multiple operation mode. Traverse operation: preset frequency and center frequency adjustable, parameter memory and recovery after power cut.
PID Control RS485 Communication Built-in PID controller (frequency can be preset)  Standard RS485 communication function
Frequency Setting Analog Input Direct voltage 0~10V, direct current 0~20mA (optional up limit and lower limit)
Digital Input Operation panel setting, RS485 port setting, UP/DOWN terminal control, or combined with analog input
Output Signal Digital Output 2-channel Y terminal open collector output and 2-channel programmable relay output-TA, TB, TC (NPN version);

1-channel Y terminal open collector output and 2-channel programmable relay output-TA, TB, TC (NPN+PNP version)

Analog Output 2 channel analog signal output, output ranging within 0~20mA or 0~10V with flexibly setting, achievable output of physical quantities like set frequency, output frequency
Automatic Steady voltage Operation Dynamic steady state, static steady state, and unsteady voltage for choices to obtain the steadiest operation
Acceleration and Deceleration Time Setting 0.0s~65000.0s can be set continuously, S-type and linear type are optional
Brake Dynamic Braking Dynamic braking initial voltage, backlash voltage and dynamic braking continuous adjustable
DC Braking Halt DC braking initial frequency: 0.00~[F00.10] Max.frequency;
Braking time: 0.0~100.0s;  Braking current: 0.0%~100.0% of rated current
Low Noise Running Carrier frequency 0.5kHz~16.0kHz continuous adjustable, minimize motor noise
Speed Tracking and Restart Function Smooth restart during operation, instantaneous stop and restart
Counter A built-in counter, facilitate system integration
Operation Function Upper limit and lower limit frequency setting, frequency hopping operation, reversal running restraint, slip frequency compensation, RS485 communication, frequency control of progressive increase and decrease, failure recovery aomatically, etc.
Display Operation Panel Display Running State Output frequency, output current, output voltage, motor speed, set frequency, module temperature, PID setting, feedback, analog input and output.
Alarm There are 8 running parameter records include output frequency, set frequency, output current, output voltage, DC voltage, module temperature, power-on time, and running time when tripped by three-time faults.
Protective Function Overcurrent, overvoltage, undervoltage, module fault, electric thermal relay, overheat, short circuit, default phase of input and output, motor parameter adjustment abnormality, internal memory fault, etc.
Environment Ambient Temperature -10°C ~ +40°C (please run the VFD in derated capacity when ambient temperature is 40°C~50°C)
Ambient Humidity 5%~95%RH, without condensing drops
Surroundings Indoors (without direct sunlight, corrosive or flammable gas, oil fog and dust)
Altitude Running in derated capacity above 1000m, derate 10% for every 1000m rise.
Structure Protection Level IP20
Cooling Method Air cooling with fan control
Installation Method Wall-hanging type

Reviews

There are no reviews yet.

Be the first to review “Canroon VFD”

Your email address will not be published. Required fields are marked *

Related Products

Original price was: 2,700 ৳ .Current price is: 2,500 ৳ .

Original price was: 18,500 ৳ .Current price is: 17,000 ৳ .

Original price was: 590,000 ৳ .Current price is: 560,000 ৳ .