Description
Specifications
| Functional description | Specification index | ||
| Input | Rated Voltage, Frequency | 3-phase (4T) AC 380V, 47-63Hz; 1-phase (2S) AC 220V, 47-63 Hz | |
| Allowed Voltage Range | 3-phase (4T) AC 320V~480V; 1-phase (2S) AC 160V~260V | ||
| Output | Voltage | 14T,0~480V;12S,0~260V | |
| Freqency | Vector control: 0~500Hz V/F control: 0~1000Hz | ||
| Overload Capacity | 150% rated current 60s, 180% rated current 5s; 195% rated current 0.5s | ||
| Control Mode | V/F control, speed-sensor-less vector control (SVC) | ||
| Control Character | Frequency Setting Resolution | Analog Input | Maximum frequency X0.025% |
| Digital Setting | 0.01Hz | ||
| V/F Control | V/F Curve(voltage frequency character) | Three types: linear type; multi-point type; Nth power type V/F curve (to the power of 1.2, 1.4,1.6,1.8,2) | |
| V/F separation | 2 types: full separation, half separation | ||
| Torque Compensation | Manual setting: 0.0~30% of rated output Automatic compensation: according to output current and motor parameter | ||
| Automatic Currentlimiting and Voltage-limiting | During acceleration, deceleration or steady running, detect automatically the current and voltage of motor stator, and control it within bounds based on unique algorithm, minimize fault-trip chanc | ||
| Senseless Vector Control | Voltage Frequency Character | Adjust pressure/frequency ratio according to motor parameter and unique algorithm | |
| Torque Character | Starting torque:150% rated torque at 1.0Hz (VF control)
150% rated torque at 0.25Hz ( SVC) Running speed steady-state accuracy: ≤±0.2% of rated synchronous speed Speed fluctuation: ≤±0.5% rated synchronous speed Torque response: ≤20ms ( SVC) |
||
| Motor Parameter Self-measurement | Being able to detect parameter automatically under static state and dynamic state of motor, thus guarantee an optimum control. | ||
| Current and Voltage Restrain | Current closed-loop control, free from current impact, perfect restrain function of overcurrent and overvoltage | ||
| Undervoltage Restrain during Running | Specially for users with a low or unsteady voltage power grid: even lower than the allowable voltage range, the system can maintain the longest possible operating time based on its unique algorithm and residual energy allocation strategy | ||
| Typical Function | Multi-velocity and Traverse Operation | 16 segments programmable multi-velocity control, multiple operation mode. Traverse operation: preset frequency and center frequency adjustable, parameter memory and recovery after power cut. | |
| PID Control RS485 Communication | Built-in PID controller (frequency can be preset) Standard RS485 communication function | ||
| Frequency Setting | Analog Input | Direct voltage 0~10V, direct current 0~20mA (optional up limit and lower limit) | |
| Digital Input | Operation panel setting, RS485 port setting, UP/DOWN terminal control, or combined with analog input | ||
| Output Signal | Digital Output | 2-channel Y terminal open collector output and 2-channel programmable relay output-TA, TB, TC (NPN version);
1-channel Y terminal open collector output and 2-channel programmable relay output-TA, TB, TC (NPN+PNP version) |
|
| Analog Output | 2 channel analog signal output, output ranging within 0~20mA or 0~10V with flexibly setting, achievable output of physical quantities like set frequency, output frequency | ||
| Automatic Steady voltage Operation | Dynamic steady state, static steady state, and unsteady voltage for choices to obtain the steadiest operation | ||
| Acceleration and Deceleration Time Setting | 0.0s~65000.0s can be set continuously, S-type and linear type are optional | ||
| Brake | Dynamic Braking | Dynamic braking initial voltage, backlash voltage and dynamic braking continuous adjustable | |
| DC Braking | Halt DC braking initial frequency: 0.00~[F00.10] Max.frequency; Braking time: 0.0~100.0s; Braking current: 0.0%~100.0% of rated current |
||
| Low Noise Running | Carrier frequency 0.5kHz~16.0kHz continuous adjustable, minimize motor noise | ||
| Speed Tracking and Restart Function | Smooth restart during operation, instantaneous stop and restart | ||
| Counter | A built-in counter, facilitate system integration | ||
| Operation Function | Upper limit and lower limit frequency setting, frequency hopping operation, reversal running restraint, slip frequency compensation, RS485 communication, frequency control of progressive increase and decrease, failure recovery aomatically, etc. | ||
| Display | Operation Panel Display | Running State | Output frequency, output current, output voltage, motor speed, set frequency, module temperature, PID setting, feedback, analog input and output. |
| Alarm | There are 8 running parameter records include output frequency, set frequency, output current, output voltage, DC voltage, module temperature, power-on time, and running time when tripped by three-time faults. | ||
| Protective Function | Overcurrent, overvoltage, undervoltage, module fault, electric thermal relay, overheat, short circuit, default phase of input and output, motor parameter adjustment abnormality, internal memory fault, etc. | ||
| Environment | Ambient Temperature | -10°C ~ +40°C (please run the VFD in derated capacity when ambient temperature is 40°C~50°C) | |
| Ambient Humidity | 5%~95%RH, without condensing drops | ||
| Surroundings | Indoors (without direct sunlight, corrosive or flammable gas, oil fog and dust) | ||
| Altitude | Running in derated capacity above 1000m, derate 10% for every 1000m rise. | ||
| Structure | Protection Level | IP20 | |
| Cooling Method | Air cooling with fan control | ||
| Installation Method | Wall-hanging type | ||

Reviews